• HUATEC GROUP CORPORATION
    Bob
    Type de pouce d'Astm E114-15 acier au carbone 1018 de bloc d'essai d'étalonnage Mini Iiw 2
  • HUATEC GROUP CORPORATION
    William
    Type de pouce d'Astm E114-15 acier au carbone 1018 de bloc d'essai d'étalonnage Mini Iiw 2
  • HUATEC GROUP CORPORATION
    À M
    Type de pouce d'Astm E114-15 acier au carbone 1018 de bloc d'essai d'étalonnage Mini Iiw 2
  • HUATEC GROUP CORPORATION
    Lion
    Type de pouce d'Astm E114-15 acier au carbone 1018 de bloc d'essai d'étalonnage Mini Iiw 2
Personne à contacter : Noah
Numéro de téléphone : +8613911115555
Je suis désolé. : +8613910983110

Twin NiCr Sensitivity Panels NiCr Twin Cracked TypeⅠASTM E1417 AMS 2647D ISO 3452 JIS Z 2343-3

Lieu d'origine Pékin
Nom de marque HUATEC
Certification ISO, CE, GOST
Numéro de modèle TypeⅠ
Quantité de commande min 1 pièces
Détails d'emballage Paquet d'exportation standard
Délai de livraison 1-4days
Conditions de paiement T/T, PayPal, Western Union
Capacité d'approvisionnement 500 pièces par mois

Contactez-moi pour des échantillons gratuits et des coupons.

Je suis désolé.:0086 18588475571

Je suis sur WeChat.: 0086 18588475571

Skype est là.: sales10@aixton.com

Si vous avez des préoccupations, nous fournissons une aide en ligne 24 heures sur 24.

x
Détails sur le produit
Matériel NiCr Couleur Pour les pièces détachées
Nom SpécimenⅠ de Typetest Les normes 3452-3:1998 D'OIN (E), 2343-3:2001 DE JIS Z
Nom du produit Inspection de pénétrant de colorant La norme 2343-3:2001 DE JIS Z
Mettre en évidence

nicr penetrant testing

,

penetrant testing panels

Laisser un message
Description de produit

TypeⅠASTM E1417, AMS 2647D, ISO 3452-3, JIS Z 2343-3 Twin NiCr Sensitivity Panels NiCr Twin Cracked Penetrant Test Panels

 

TypeⅠPenetrate block :ISO 3452-3:1998(E),JIS Z 2343-3:2001

Twin NiCr Sensitivity Panels,NiCr Twin Cracked Penetrant Test Panels

ISO 3452-3 Type 1 Test Panel

 

The NiCr Twin Cracked Penetrant Test Panels are used for comparing and evaluating sensitivity and performance of Dye Penetrants.

They are available in 10, 20, 30 and 50 microns (0.0004, 0.0008, 0.0012, 0.002 inch) flaw depth.

Each set consists of a pair of identical panels marked A and B with manufacturer`s certification and crack photograph.

These panels are made by plating hard Nickel Chromium alloy on a 2mm thick brass substrate and stressing the panel in tension. The hard NiCr is brittle in comparison to the brass substrate so that the cracks created in the plated layer are limited to the thickness of the layer. The panel is then cut in half perpendicular to the direction of the cracks thus creating a matching pair of virtually identical cracks of controlled depth.

NiCr Panels are used to compare new and used penetrants and can also be used for comparing performance of different penetrant materials or different processing techniques.

Sensitivity* (unofficial) Fluorescent Penetrant Sensitivity Levels are established by the USAF Laboratory under highly controlled conditions. Sensitivity testing is not something the penetrant manufacturer or user can do. What you can do is compare samples using appropriate NiCr Cracked Panels.

 

 

Crack Depth

 

Level

50 μm 1, 2, 3, 4
30 μm 2, 3, 4
20 μm 3, 4
10 μm 4


Guaranteed to be equivalent to both Sherwin and Magnaflux supplied panels.

Specifications Compliance: ASTM E1417, AMS 2647D, ISO 3452-3, JIS Z 2343-3

 

 

Standard delivery:

YM-B block 1 set

Calibration certificate 1 pc

Case 1 pc